Large gate valve and fire protection piping at a water service connection.

Purveyor-ready records

Backflow Testing Software

Certified assembly tests and forward-flow results on the same location.

What a backflow test records

Fire protection backflow work usually produces two different results, and they should not be written up as the same test. Where NFPA 25 is adopted, a backflow prevention assembly installed in fire protection piping gets a forward-flow test so the assembly is not restricting the system. The water purveyor separately requires a certified test of the assembly itself, on the purveyor’s form, for a reduced-pressure zone, double check, or pressure vacuum breaker.

The technician records the assembly type, size, serial number, where it sits on the property, the gauge readings, and whether it passed. A failed check becomes a repair with those readings attached, not a line in a notebook that never reaches the office.

Retest dates follow the purveyor and, for the forward-flow test, the adopted NFPA 25 edition. Optic keeps both on the location you already service for sprinklers.

Built on Optic inspections & reporting

Faster capture. Cleaner inspection reports.

Optic ties technicians, equipment, photos, and PDF output to the same record—similar to how your team uses Inspections, full inspection profiles, and generated report packages in the app today.

Rough order-of-magnitude: backflow test report turnaround

Typical competitor field software20–40 min / assembly
Optic (internal testing)5–10 min

Baseline: turnaround in typical competitor tooling for the same assembly. Internal testing targets ~75% faster PDFs—gauge readings and check results flow straight into customer-ready output.

What “cleaner reports” means

  • Gauge readings with timestamp and calibration context.
  • Automatic reminders for annual / triennial / five-year milestones per purveyor rules.
  • Batch submittals to municipalities that still want fax-era formatting—without retyping.

Code & water authority context

Educational references only—always confirm the adopted edition and local amendments with your AHJ.

NFPA 25

Where NFPA 25 is adopted, a backflow prevention assembly installed in fire protection piping is part of water-based ITM. The forward-flow test checks that the assembly is not restricting the fire protection system. It is not the purveyor’s certified backflow test.

Purveyor / plumbing rules

The certified test of a reduced-pressure zone, double check, or pressure vacuum breaker follows the water purveyor, AWWA guidance, and the state plumbing code. Those retest dates belong on the same assembly as the fire protection visit.

Field capture → office handoff

The same record powers dispatch, inspection history, and customer PDFs.

That mirrors how Optic already connects work orders, locations, attachments, and report generation—so your trade-specific narrative is not trapped in a one-off template.

  • Fewer copy-paste errors between the truck and billing.
  • Consistent vocabulary for deficiencies across crews.
  • Audit-friendly history when ownership or insurers ask questions later.
Close-up of valve wheels and piping in a utility space.

Section 01

Purveyor rules + fire routes = one customer record

Many contractors run backflow alongside sprinkler or alarm routes. When those programs live in different competitor systems, someone always misses a retest letter.

Optic keeps assemblies as first-class assets tied to the same locations you already maintain for fire protection—so route planning and customer reporting stay synchronized.

Where Optic shows up in your workflow

Each one maps to something Optic already tracks: customers, locations, inspections, and the reports you send.

Municipality-specific cadence

Model retest rules per water district without a side calendar.

Customer self-service hooks

Optional portal views so owners see upcoming tests before they become violations.

Cleaner test reports

Standard layouts that list serial numbers, sizes, and results in the order AHJs expect.

Documentation your AHJ can follow

  • Map assemblies to NFPA 25 domestic/fire pump interfaces when both trades touch the same riser.
  • Keep test kit calibration records discoverable during liability reviews.

Optic does not replace professional judgment or engineering of record. Use these references as a starting point for conversations with your authority having jurisdiction.

Questions

What does backflow testing software record?

The assembly type, size, serial number, location, gauge readings, and pass or fail. Fire protection contractors also record the forward-flow test NFPA 25 calls for when an assembly is installed in fire protection piping. That is not the same test as the purveyor’s certified backflow test.

Can purveyor due dates live with the fire protection account?

Yes. The assembly sits on the same customer and location as the sprinkler system, so the retest date is not kept in a separate spreadsheet.

What happens when an assembly fails?

The failed check stays on the assembly, with the gauge readings, and can become the repair work order.

See Backflow Prevention workflows in Optic

Tell us about your mix of routes, report formats, and regions—we will map what you see here to the modules your team already uses in the app.